SpecificationsDocumentsDescriptionDimensions
| | |
Accuracy (Best Fit Straight Line) | | N/A |
Alarms | | No |
Availability | | Global |
Calibration and Data Printout | | No |
Combined Humidity and Temperature Sensor | | No |
Covered Device | | No |
Hysteresis | | ±3 %RH |
Interchangeability | | 0 %RH to 59% RH ±5 %RH, 60 %RH to 100 %RH ±8 %RH |
Long-term Stability (Drift) | | ±1.2 %RH for five years; ±0.25 %RH each year |
MoistureDust Filter | | No |
Operating Humidity Range | | 0% RH to 100 %RH |
Operating Temperature | | -40 °C to 85 °C [-40 °F to 185 °F] |
Output Signal | | Analog voltage |
Package Type | | 2,54 mm [0.100 in] lead pitch SIP |
Repeatability | | ±0.5% RH |
Response Time | | 5 s 1/e in slow moving air |
Series Name | | HIH-4010/4020/4021 |
Settling Time | | 70 ms max. |
Stability at 50% RH | | ±0.5 %RH |
Supply Current | | 500 µA |
Supply Voltage | | 5.8 Vdc |
Temperature Sensing Type | | N/A |